A360 aluminium alloy housing with weather-resistant protective
powder coating
All F ports meet SCTE IPS-SP-400 standard and are waterproof
at 34KPa water pressure for 4 hours
1KV blocking capacitors on each F port for DC/hum protection
Patented AC/RF bypass device
Patented 360° 4 prong strong holding force seizure
Distortion best solution:
1. Hum modulation at 90VA/10A, 5-10MHz < -60dB, 11-749MHz
< -70dB, 750-1000MHz < -60dB
2. Inter modulation on all F ports < -105dB
3. 2nd harmonics on all F ports < -110dB
Power passing: 12A, 60/90VAC, 60Hz
RFI < -100dB
High isolation and tap return loss for return path
Flatness: ±0.35dB
100% leakage test and signal continuity test before packaging.